Check out the comparison table of the top features of the
American 40-gallon gas water heaters, including direct, power and
atmospheric vented models.
Specs. --------- Model |
Input (Btu) x1000 |
First Hour Delivery (GPH) |
Recov- ery Rate (90F) (GPH) |
Efficie- ncy |
Approx. Height/ Type (Inch) |
Vent Type |
Warr anty |
Direct Vent | |||||||
DVG62-40S38-NOV | 38 | 72 | 41 | 0.60 | 64 |
DV | 6 |
Ultra Low-NOx | |||||||
UG61-40T40-3NV | 40 | - | 41 | 0.59 | 62 |
A | 6 |
UG62-40T40-3NV | 40 | - | 41 | 0.62 | 62 |
A | 6 |
Ultra Low-NOx Direct Vent | |||||||
DVUG62-40S36-NV | 36 | - | 39 | 0.59 | 65 | DV | 6 |
Ultra Low-NOx Power Vent | |||||||
PVUG62-40T42-NV | 42 | 69 | 42.6 | 0.68 | 67 | PV | 6 |
PowerFlex Power Vent | |||||||
PVG62-40S40-NVS | 40 | 73 | 44.7 | 0.70 | 59 | PV | 6 |
PVG62-40T50-NVS | 50 | 90 | 55.9 | 0.70 | 68 | PV | 6 |
PVG62-40T42-NV | 42 | - | 42.6 | 0.67 | 67 | PV | 6 |
PowerFlex Power Direct Vent | |||||||
PDVG62-40T42-NV | 42 | - | 42.6 | 0.67 | 67 | PDV | 6 |
Mobile Home FVIR | |||||||
MFG61-40T40-3N0V | 40 32 |
- | 41 33 |
0.59 | 61 | A | 6 |
Flame Guard | |||||||
BFG91-40S40-3NOV | 40 36 |
- | 40.5 36.5 |
0.59 | 52 | A | 9 |
BFG91-40T40-3NOV | 40 36 |
- | 40.5 36.5 |
0.59 | 62 | A | 9 |
BFG122-40T40-3NOV | 40 36 |
- | 40.5 36.5 |
0.63 | 62 | A | 12 |
BFG61-40S40-3NOV | 40 36 |
- | 40.5 36.5 |
0.59 | 52 | A | 6 |
BFG61-40T40-3NOV | 40 36 |
- | 40.5 36.5 |
0.59 | 62 | A | 6 |
BFG62-40S40-3NOV | 40 36 |
- | 40.5 36.5 |
0.62 | 52 | A | 6 |
BFG62-40T40-3NOV | 40 36 |
- | 40.5 36.5 |
0.63 | 62 | A | 6 |
Mobile Home Sealed Combustion | |||||||
MHSCG-62-40T32-3NV | 32 | - | 33 | 0.59 | 56 | DV | 6 |
Vent type:
A-Atmospheric, PV-Power Vent, DV-Direct Vent, PDV-Power Direct Vent
Gas type:
For propane, substitute "P" for "N" in the model number.
If the table cell has two values... upper values are for natural gas while lower values are for propane.
Models with the energy factor, EF, of 0.67 and over are Energy Star.
Features --------- Model |
Anode Rod |
Advanced Diagnostic |
Intellig. Control Logic |
Lime Fighter Dip Tube |
Low NOx Design |
Igniter |
Direct Vent | ||||||
DVG62-40S38-NOV | 1 Core- Gard |
LED | Yes | Diffuser | No | Piezo |
Ultra Low-NOx | ||||||
UG61-40T40-3NV | 1 (Heavy Duty) |
Yes | Yes | Yes | Yes | Piezo |
UG62-40T40-3NV | 1 (Heavy Duty) |
Yes | Yes | Yes | Yes | Piezo |
Ultra Low-NOx Direct Vent | ||||||
DVUG62-40S36-NV | 1 (Heavy Duty) |
No | No | Stand. | Yes | Piezo |
Ultra Low-NOx Power Vent | ||||||
PVUG62-40T42-NV | 1 (Al) | Yes | Yes | Yes | Yes | Electr. |
PowerFlex Power Vent | ||||||
PVG62-40S40-NVS | 1 | LED | No | Yes | No | HSI |
PVG62-40T50-NVS | 1 | LED | No | Yes | No | HSI |
PVG62-40T42-NV | 1 (Heavy Duty) | Yes | No | Stand. | Yes | Electr. |
PowerFlex Power Direct Vent | ||||||
PDVG62-40T42-NV | 1 (Heavy Duty) | Yes | No | Stand. | Yes | Electr. |
Mobile Home FVIR | ||||||
MFG61-40T40-3N0V | 1 | LED | Yes | Stand. | Yes | Piezo |
Flame Guard | ||||||
BFG91-40S40-3NOV | 1 (Heavy Duty) |
Yes | Yes | Yes | Yes | Piezo |
BFG91-40T40-3NOV | 1 (Heavy Duty) |
Yes | Yes | Yes | Yes | Piezo |
BFG122-40T40-3NOV | 1 (Heavy Duty) |
Yes | Yes | Yes | Yes | Piezo |
BFG61-40S40-3NOV | 1 (Heavy Duty) |
Yes | Yes | Yes | Yes | Piezo |
BFG61-40T40-3NOV | 1 (Heavy Duty) |
Yes | Yes | Yes | Yes | Piezo |
BFG62-40S40-3NOV | 1 (Heavy Duty) |
Yes | Yes | Yes | Yes | Piezo |
BFG62-40T40-3NOV | 1 (Heavy Duty) |
Yes | Yes | Yes | Yes | Piezo |
Mobile Home Sealed Combustion | ||||||
MHSCG-62-40T32-3NV | 1 (Heavy Duty) |
No | No | No | No | Pilot |
The CoreGard anode rod has a stainless steel core for the superior metal tank protection and longer life.
The Lime-Fighter and diffuser dip tube are used to reduce the lime and sediment buildup.
Intelligent Control Logic is a small microprocessor that is used for better accuracy and performance of the water heater.
HSI - Hot surface ignition
American
American tankless
American 30-gal
American 40-gal
American 50-gal
American heat pump